Item Name : Circuit Breaker
-
CAGE Code: 81541
Part number AP-1-1-72-702 , Circuit Breaker by Sensata Technologies Inc with NSN 5925013819403 is now available in our ready-to-ship inventory. Are you interested in a quick quote for the part number AP-1-1-72-702? If so, just fill out the Request for Quote (RFQ) form above and click submit.
We have one of the fastest RFQ response times in the industry at only 15 minutes, simply complete the form to get started.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number AP-1-1-72-702 with NSN 5925-01-381-9403, 5925013819403
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-381-9403 Item Description: Circuit Breaker | 5925 | 013819403 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ap-1-1-72-702 | 5 | 2 | 5 |
Characteristics Data of NSN 5925-01-381-9403, 5925013819403
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 NOMINAL AT 135 PCT SINGLE LOCATION AND 60.000 MAXIMUM AT 135 PCT SINGLE LOCATION |
CQQC | Trip Release Duty Cycle | CONTINUOUS SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
ABXD | Bushing Length | 0.380 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
ADAT | Body Width | 0.625 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE ONE |
CPSM | Internal Trip Release Configuration | SERIES/RELAY TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.605 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type And Quantity | 2 WIRE HOOK |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.0 AMPERES AC SINGLE LOCATION AND 7.0 AMPERES DC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRW | Actuator Function | TRIP-RESET |
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED |