Quote for Part 064-18882-01 by Oeco Corporation - NSN 5950-01-334-6631 Part
-
Part Number: 064-18882-01
-
Alternate P/N: 0641888201
-
Manufacturer: Oeco Corporation
-
NSN: 5950-01-334-6631 (5950013346631)
-
NIIN: 013346631
-
Item Name : Transformer Power
-
CAGE Code: 95266
Part number 064-18882-01 , Transformer Power by Oeco Corporation with NSN 5950013346631 is now available in our ready-to-ship inventory. Are you interested in a quick quote for the part number 064-18882-01? If so, just fill out the Request for Quote (RFQ) form above and click submit.
We have one of the fastest RFQ response times in the industry at only 15 minutes, simply complete the form to get started.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number 064-18882-01 with NSN 5950-01-334-6631, 5950013346631
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-334-6631 Item Description: Transformer Power | 5950 | 013346631 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
064-18882-01 | 5 | 2 | 5 |
Characteristics Data of NSN 5950-01-334-6631, 5950013346631
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 4.550 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.790 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.810 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.663 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.683 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 393.0 HERTZ MINIMUM SINGLE COMPONENT AND 407.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 527.0 WATTS SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 32.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 22.50 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB, SOLDER LUG |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
ABKW | OVERALL HEIGHT | 3.380 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.380 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 204.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
We are proud to supply every branch of the United States military
Top National Stock Numbers
5306013334523 |
7490013953355 |
6140014469498 |
7025015900737 |
3130015369045 |
4730009541281 |
6240001557836 |
5965016488042 |
5330012852788 |
7210000527327 |