Quote for Part 2567-249-00 by Lorain Electronics Corp - NSN 5925-01-161-2945 Part
-
Part Number: 2567-249-00
-
Alternate P/N: 256724900
-
Manufacturer: Lorain Electronics Corp
-
NSN: 5925-01-161-2945 (5925011612945)
-
NIIN: 011612945
-
Item Name : Circuit Breaker
-
CAGE Code: 06434
Part number 2567-249-00 , Circuit Breaker by Lorain Electronics Corp with NSN 5925011612945 is now available in our ready-to-ship inventory. Are you interested in a quick quote for the part number 2567-249-00? If so, just fill out the Request for Quote (RFQ) form above and click submit.
We have one of the fastest RFQ response times in the industry at only 15 minutes, simply complete the form to get started.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number 2567-249-00 with NSN 5925-01-161-2945, 5925011612945
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-161-2945 Item Description: Circuit Breaker | 5925 | 011612945 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2567-249-00 | 5 | 1 | C | A |
Characteristics Data of NSN 5925-01-161-2945, 5925011612945
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.769 INCHES MINIMUM AND 5.831 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.041 INCHES MINIMUM AND 2.103 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.516 INCHES MINIMUM AND 3.578 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.995 INCHES MINIMUM AND 1.057 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.719 INCHES MINIMUM AND 2.781 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.995 INCHES MINIMUM AND 1.057 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.172 INCHES MINIMUM AND 3.265 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBBL | FEATURES PROVIDED | HIGH INRUSH PROTECTION |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 24.0 DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERVOLTAGE SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 120.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FIRST LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT FIRST LOCATION AND 70.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
CRTK | SWITCH TERMINAL TYPE | TURRET |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
FREQ | FREQUENCY IN HERTZ | 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 11.000 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
Recently Viewed Parts
We are proud to supply every branch of the United States military
Top National Stock Numbers
5306013334523 |
7490013953355 |
6140014469498 |
7025015900737 |
3130015369045 |
4730009541281 |
6240001557836 |
5965016488042 |
5330012852788 |
7210000527327 |