Quote for Part 3010-5111 by Iet Labs Inc - NSN 5950-00-683-3641 Part
-
Part Number: 3010-5111
-
Alternate P/N: 30105111
-
Manufacturer: Iet Labs Inc
-
NSN: 5950-00-683-3641 (5950006833641)
-
NIIN: 006833641
-
Item Name : Transformer Power A
-
CAGE Code: 62015
Part number 3010-5111 , Transformer Power A by Iet Labs Inc with NSN 5950006833641 is now available in our ready-to-ship inventory. Are you interested in a quick quote for the part number 3010-5111? If so, just fill out the Request for Quote (RFQ) form above and click submit.
We have one of the fastest RFQ response times in the industry at only 15 minutes, simply complete the form to get started.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number 3010-5111 with NSN 5950-00-683-3641, 5950006833641
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-683-3641 Item Description: Transformer Power A | 5950 | 006833641 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3010-5111 | 6 | 1 | C | 9 |
Characteristics Data of NSN 5950-00-683-3641, 5950006833641
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.125 INCHES NOMINAL |
ADAT | BODY WIDTH | 5.375 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.562 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.6 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRMJ | WINDING POWER RATING | 300.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 135.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 SOLDER STUD |
Part 3010-5111 With Different Manufacturers
We are proud to supply every branch of the United States military
Top National Stock Numbers
5306013334523 |
7490013953355 |
6140014469498 |
7025015900737 |
3130015369045 |
4730009541281 |
6240001557836 |
5965016488042 |
5330012852788 |
7210000527327 |