Part Number: AP-12-1RC-25581-1
-
Alternate P/N: AP121RC255811
-
Manufacturer: Henley Marine Inc
-
NSN: 5925-01-424-1710 (5925014241710)
-
NIIN: 014241710
-
Item Name : Circuit Breaker
-
CAGE Code: 20227
Part number AP-12-1RC-25581-1 , Circuit Breaker by Henley Marine Inc with NSN 5925014241710 is now available in our ready-to-ship inventory. Are you interested in a quick quote for the part number AP-12-1RC-25581-1? If so, just fill out the Request for Quote (RFQ) form above and click submit.
We have one of the fastest RFQ response times in the industry at only 15 minutes, simply complete the form to get started.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number AP-12-1RC-25581-1 with NSN 5925-01-424-1710, 5925014241710
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-424-1710 Item Description: Circuit Breaker | 5925 | 014241710 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ap-12-1rc-25581-1 | 5 | 1 | C | A |
Characteristics Data of NSN 5925-01-424-1710, 5925014241710
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 0.500 AMPERES AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |